CSIR Central

A dual enzyme amperometric biosensor for monitoring organophosphorous pesticides.

IR@CFTRI: CSIR-Central Food Technological Research Institute, Mysore

View Archive Info
 
 
Field Value
 
Relation http://ir.cftri.com/8286/
 
Title A dual enzyme amperometric biosensor for monitoring organophosphorous pesticides.
 
Creator Gouda, M. D.
Thakur, M. S.
Karanth, N. G.
 
Subject 03 Enzyme Biotechnology and Engineering
 
Description An amperometric biosensor consisting of two enzyme membranes, one a potato layer rich in acid phosphatase and the other an immobilized glucose oxidase membrane, when operated in conjunction with a Clark type dissolved O2 electrode, detected paraoxon at 1
 
Date 1997
 
Type Article
PeerReviewed
 
Format application/pdf
 
Language en
 
Rights
 
Identifier http://ir.cftri.com/8286/1/Biotechnology%20Techniques%2C%20Vol%2011%2C%20No%209%2C%20September%201997%2C%20pp.%20653%E2%80%93655.pdf
Gouda, M. D. and Thakur, M. S. and Karanth, N. G. (1997) A dual enzyme amperometric biosensor for monitoring organophosphorous pesticides. Biotechnology Techniques, 11 (9). 653-655; 8 ref..