CSIR Central

A comparative study of DC and pulse gold electrodeposits

IR@CECRI: CSIR-Central Electrochemical Research Institute, Karaikudi

View Archive Info
 
 
Field Value
 
Title A comparative study of DC and pulse gold electrodeposits
 
Creator Mohan, S.
Raj, V.
 
Subject Industrial Metal Finishing
 
Description Gold deposits were formed on AA 1100 aluminium alloy using a simple chemical pretreatment both by direct current plating (DCP) and pulsed current deposition (PCD) methods. The surface properties of the gold deposits such as adhesion, porosity, surface morphology and corrosion resistance formed by both DCP and PCD methods were compared by analysing them using adhesion and porosity tests, scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). From the analyses, it is observed that the gold film formed by the PCD method has a better corrosion resistance, less porosity and reduced grain size compared to that formed by the DCP method.
 
Publisher Maney Publishing
 
Date 2005
 
Type Article
PeerReviewed
 
Format application/pdf
 
Identifier http://cecri.csircentral.net/220/1/113-2005.pdf
Mohan, S. and Raj, V. (2005) A comparative study of DC and pulse gold electrodeposits. Transactions of the Institute of Metal Finishing, 83 (2). pp. 72-76. ISSN 0020-2967
 
Relation http://cecri.csircentral.net/220/