CSIR Central

Standardisation of Y-90 and determination of calibration factors for Y-90 microspheres (resin) for the NPL secondary ionisation chamber and a Capintec CRC-25R

IR@NPL: CSIR-National Physical Laboratory, New Delhi

View Archive Info
 
 
Field Value
 
Title Standardisation of Y-90 and determination of calibration factors for Y-90 microspheres (resin) for the NPL secondary ionisation chamber and a Capintec CRC-25R
 
Creator Ferreira, Kelley M.
Fenwick, Andrew J .
Arinc, Arzu
Johansson, Lena C.
 
Subject Nuclear Chemistry
Organic Chemistry
Nuclear Science Technology
 
Description The use of Y-90 resin microspheres (SIR-Spheres (R) microspheres) in Nuclear Medicine has dramatically increased in recent years due to its favourable outcome in the treatment of liver cancer and liver metastases (Rajekar et al., 2011). The measurement of administered activity before and residual activity after treatment in radionuclide calibrators is required to determine total activity delivered to the patient. In comparison with External Beam Radiotherapy (EBRT) where administered doses are often know to within +/- 5%, the actual administered activity in nuclear medicine procedures may only be known to within +/- 20% and subsequent dose calculations can result in even larger uncertainties (Fenwick et al., 2009). It is a well-recognised issue that ion chambers are instruments that are sensitive to the measurement geometry and matrix of a source, in particular for pure beta or low energy (< 100 keV) x-ray emitters (Gadd et al., 2006). This paper presents new calibration factors for NPL secondary standard ionisation chamber system (Vinten 671) and a Capintec CRC-25R radionuclide calibrator along with a discussion of the measurement problems associated with this radionuclide and matrix. Calibration of the NPL secondary standard system for this measurement matrix will enable NPL to provide standards for the Nuclear Medicine community and consequently increase the measurement capability.
 
Publisher Elsevier
 
Date 2016-03
 
Type Article
PeerReviewed
 
Format application/pdf
 
Identifier http://npl.csircentral.net/2359/1/Standardisation.pdf
Ferreira, Kelley M. and Fenwick, Andrew J . and Arinc, Arzu and Johansson, Lena C. (2016) Standardisation of Y-90 and determination of calibration factors for Y-90 microspheres (resin) for the NPL secondary ionisation chamber and a Capintec CRC-25R. Applied Radiation and Isotopes, 109. 226 -230. ISSN 0969-8043
 
Relation http://npl.csircentral.net/2359/