Dynamic response and effect of apertures on explosion parameters of flameproof apparatus
IR@CIMFR: CSIR-Central Institute of Mining and Fuel Research, Dhanbad
View Archive InfoField | Value | |
Title |
Dynamic response and effect of apertures on explosion parameters of flameproof apparatus
|
|
Creator |
Vishwakarma, R.K.
|
|
Subject |
Flame Proof Laboratory
|
|
Description |
Explosion parameters for closed flameproof apparatus are changed when apertures like gap (e.g. push button) and porous structures (breathing element) are introduced on the cover or wall of the flameproof enclosures. Similarly, an interconnecting tube between two enclosures, results in significant change in explosion parameters. It is observed that the maximum explosion pressure, maximum rate of pressure rise and severity index are higher for enclosures with apertures on cover or body than that of enclosures without apertures. In case of two interconnected identical enclosures, the explosion parameters are increased in the secondary enclosure and higher than that of primary enclosure and also of isolated enclosure.
|
|
Publisher |
Elsevier
|
|
Date |
2015-01
|
|
Type |
Article
PeerReviewed |
|
Format |
application/pdf
|
|
Identifier |
http://cimfr.csircentral.net/1734/1/vishwakarma2015.pdf
Vishwakarma, R.K. (2015) Dynamic response and effect of apertures on explosion parameters of flameproof apparatus. Journal of Loss Prevention in the Process Industries , 33. pp. 245-249. ISSN 0950-4230 |
|
Relation |
http://cimfr.csircentral.net/1734/
|
|