Thermal Design and Analysis of Collector for C band 250 kW CW Klystron

IR@CEERI: CSIR-Central Electronics Engineering Research Institute, Pilani

View Archive Info
 
 
Field Value
 
Title Thermal Design and Analysis of Collector for C band 250 kW CW Klystron
 
Creator Lamba, OS
Kaushik, M
Kumar, S
Gupta, A
Gupta, V
Sarita, .
Pal, D
Kant, D
Joshi, LM
 
Subject Klystrons
 
Description Thermal design of the collector in high power klystron plays a crucial role in overall design of klystron. Spent electron beam, after giving a part of its kinetic energy to RF fields, strikes on the inner surface of collector and dissipates its remaining energy in the form of the heat. In case of high average power tubes, the energy deposited on the collector may damage the collector if the heat is not removed efficiently. The overall dimensions and the shape of the collector depend on the operating voltage and the average power of the beam. This paper presents the thermal design of the collector of a 250 KW C band Klystron under development. Thermal simulation has been done by using ANSYS 11.0 (multi-physics). The outer surface of the collector has been grooved to increase cooling. Design results are presented for water-cooling with different flow rates and channel dimensions.
 
Date 2010
 
Type Conference or Workshop Item
PeerReviewed
 
Format application/pdf
 
Identifier http://ceeri.csircentral.net/71/1/59_2009%28i%29.pdf
Lamba, OS and Kaushik, M and Kumar, S and Gupta, A and Gupta, V and Sarita, . and Pal, D and Kant, D and Joshi, LM (2010) Thermal Design and Analysis of Collector for C band 250 kW CW Klystron. In: 2010 National Conference on Electronics, Computers and Communications ( NCECC-2010), March 6-7, 2010, Gwalior (M.P.). (Submitted)
 
Relation http://ceeri.csircentral.net/71/